Aqua Water System
     
     
 
 
USEFUL INFORMATIONS
 

SYMPTOM

PROBABLE CAUSE

UNDERLYING REASON

TO RECTIFY

SOLUTION

CLOUDY WATER

Build up dirth and pollution

Insufficient chlorine
or poor filtration
Backwash fitler then super chlorinate 10 ppm of free chlorine. Add flocculant to polish water. CLARIS Precipitating
hth or CLARIS Chlorine Granular
CLARIS Anti-algae
CLARIS Transparent

Start of algae growth

Insufficient levels of chlorine

Prevent recurrence

Superchlorinate. Backwash filter after 24 hours. Maintain chlorine level between 2 - 3 ppm. Prevent to growth algae.

hth or CLARIS Chlorine Granular
CLARIS Anti-algae
CLARIS Control
Chlorine ineffective  Ineffective filtration    Dispersed grains Check stabilizer level      
Old filter blocked
Sedimented salts because of high pH or Alkalinity

Add fresh water and chlorinate by chlorine.

Check alkalinity and filter cartridge. Adjust pH and alkalinity.

Advice your hth swimming pool service
CLARIS pH -

UNPLEASANT WATER. SORE EYES, THROAT.

ITCHING SKIN

High combined chlorine Detergents from cleaning compounds in pool water  Water too acidic or alkaline Breakpoint chlorination not being achieved
Reaction between chlorine and detergent
pH too low or too high
Superchlorinate. Use biodegradable detergents. Bring pH to within parameters recommended.

hth
CLARIS Pak
CLARIS pH - / pH +

CHLORINE LEVEL DIFFICULT TO MAINTAIN In outdoor pools sunlight destroys chlorine
Built up pollutants or chlorine not getting to pool.
Chlorine is not stabilized
Insufficient chlorination
Blockage or mulfunction of chlorine dosing system
Use stabilizator or stabilized  chlorine. Superchlorinate. Raise the disinfectant.      
Check injector, pump and auto controller.
CLARIS Stabilizator CLARIS Chlorine Granular
CLARIS Chlorine Granular
CLARIS Anti-algae

APPARENT INABILITY TO GET CHLORINE READING ON TEST KIT IN SPITE OF CHLORINE ADDITION

Chlorine level may be too high

Too much chlorine can spoil test tablets

De-chlorinate. If very high reduce with chemicals or dilute.

Advise your swimming pool service

pH TOO LOW

Too much pH corrective getting to pool

Auto control out of calibration or mulfunction

Check out pH corrective system and auto control.

CLARIS pH +

pH TOO HIGH Insufficient pH corrective being added or applied incorrectly or high alkalinity Possible malfunction of system Check out  auto control/ calibration.
Maintain pH between 7,2 - 7,6
Reduce alkalinity to 80-120 ppm.
CLARIS pH -
CLARIS pH -
pH LOCKED

High levels of alkalinity

Topping up from mains water can increase alkalinity in hard water areas

Check pH. Reduce alkalinity to 80-120 ppm.

CLARIS pH -
Advise your swimming pool service

DIRTH ON POOL WALL AT WATER LINE

Built up body fats, sweat, sun tun oil and cosmetics

Irregular cleaning of surfaces

Clean with biodegradable chemical

CLARIS Pak

pH LEVELS ERRATIC

Insufficient bicarbonates to buffer pH

Low total alkalinity

Add bicarbonate to raise alkalinity to 80-120 ppm.

CLARIS pH +
Advise your swimming pool service

POOL WALLS FEEL SLIMY

Algae growth

Insufficient chlorination and pool wall brushing

Superchlorinate to kill algae. Sweep or vacuum debris. Prevent re-occurence with algicide. hth or
CLARIS Chlorine Granular
CLARIS Anti-algae
CLARIS Control

ROUGH SCALE FORMED ON POOL SURFACES AT WATER LINE

Water out of “balance”

Ratio of calcium hardness to total alkalinity incorrect

Check levels of pH, Alkalinity and calcium are within parameters recommended

CLARIS Pak

SHARP EDGES AROUND TILES

Grout being leached by water

Mains water too soft

Regrout the pool. Increase calcium levels to min. 350 ppm and maintain. Consider change of sanitizer (calcium hypochlorite) to prevent reoccurrence.

hth

INEFFECTIVE FILTRATION

Sand Filter
Is sand level correct?
NO...
YES...

Is air being sucked into the fitler?

Sand is not enough for filtration
Blocked filter or filtration needs assistance
Air will affect the efficiency of the fitler
Renew or top up sand. Backwash filter and use flocculant. Check all joints pre-pump, gaskets on strainer pots and look for air being drawn into the system. Advise your swimming pool service
CLARIS Precipitating

Cartridge Filter

NO...
YES...
Is the cartridge clean and a good condition?

Filter is not filtering.                     
The service of the filter is necessary
Change cartridge.
Use coagulant/flocculant and backwash.
Advise your swimming pool service
CLARIS Precipitating

DISINFECTANT IS USED TOO MUCH

Little cyanuric acid

Preventation of chlorine from U.V.  becomes less

Put cyanuric acid.
( 40 - 60 ppm )

CLARIS Stabilizator

High Heat

Speed up chlorine reactions

Superchlorinate.

CLARIS Chlorine Granular

Too many swimmer, too much fouling

High oxidation demand appears.

Superchlorinate.

CLARIS Chlorine Granular

LIGHTER HAIR COLOUR

Making wrong test

High chlorine
( < 15 ppm )
Sodium sulfate or sodium bisulfate.  

GETTING WHITE SWIMMING SUITS

Old test tablets

High chlorine
( < 15 ppm )
Use sodium tiosulfate.  

SCALE FORMATION IN SWIMMING POOL WALLS, PIPES, FILTERS, HEATINGS

High pH

Calcium carbonate mixture is over

Take down pH with acid.

CLARIS pH -

High levels of alkalinity

Calcium carbonate mixture is over

Take down alkalinitiy with acid

CLARIS pH -

 
 
 
 
 

Copyright © Aqua Water System 2006